MT-510A Welding Transformer
CHARACTERISTIC
Specification / Rating
·
MT-Rated Primary Voltage 220Vac, ±10%, 50/60Hz
·
Rated Secondary Voltage (without load) OFF,1.2, 1.8, 2.5, 3.5V
·
Current (maximum) 1.6 kA
·
Duty Cycle (maximum) 4%
·
Rated Capacity at Duty Cycle 1.6 kVA
·
Input Peak Capacity (max) 5.6 kVA
·
Insulation Voltage 3 kVac for 1 minute
Physical:
·
Height 195 mm (7.68 in.)
·
Width 193 mm (7.6 in
·
Depth 288 mm (11.34 in)
·
Weight 20 kg (44 lb)
ME-35A Weld controller
Input Power Line Voltage Range 220 Vac ±10%, 50/60 Hz single phase
Output Energy (maximum) at 10% Duty Cycle 20 kVA
ME-35A Welding Control Power Consumption (maximum) 5W
PHYSICAL
Dimensions (excluding terminal strip and Welcard projections:
Height 269 mm (10.5 in.)
Width 142 mm (5.5 in)
Depth 330 mm (13.0 in.)
Weight 5 kg (11 lb)
ELECTRICAL
Number of Weld Schedules Stored in Memory 7
RMS Primary Current:
Maximum 90 A
Minimum 5 A
Feedback Control Modes:
Primary Constant Current, Secondary Constant Current, Voltage
Compensation, Single Cycle
Primary Constant Current Mode:
Initial Feedback Response Rate (maximum time required for current
to come within ±10% of current setting following start of welding) 3 cycles
Feedback Control Rate (maximum) 1 cycle
Current Accuracy (minimum) over a ±10% fluctuation in input power
line voltage or over a ±30% variation in welding resistance ±2%
Currents 1 and 2 operating range (10 A resolution) . 0.2 to 8.0 kA
Current Range Limit (100 A resolution) 0.5 to 8.0 kAAPPENDIX A:
TECHNICAL SPECIFICATIONS
ME-35A FINE SPOT WELDING POWER SUPPLY
Current Monitor Operating Range:
Upper Limit (0%=OFF) +1 to +49%
Lower Limit (0%=OFF) -1 to -49%
Squeeze Period (SQ) 0 to 99 cycles
First Upslope Period (UP1) (included as part of the Weld 1 period) 0 to 9 cycles
First Weld Period (W1) . 0 to 99 cycles
Cool Period .0 to 99 cycles
Second Upslope Period (UP2) (included as part of the Weld 2 period) 0 to 9 cycles
Second Weld Period (W2) 0 to 99 cycles
Hold Period (HO) 0 to 99 cycles
Pulsation 1 to 9 complete Weld 2 periods
Secondary Constant Current Mode:
Initial Feedback Response Rate (maximum time required for current
to come within ±10% of current setting following start of welding) 2 cycles
Feedback Control Rate (maximum) 0.5 cycle
Current Accuracy (minimum) over a ±10% fluctuation in input power
line voltage or over a ±30% variation in welding resistance ±2%
Currents 1 and 2 operating range (10 A resolution) 0.2 to 8.0 kA
Current Range Limit (100 A resolution) 0.5 to 8.0 kA
Current Monitor Operating Range:
Upper Limit (0%=OFF) +1 to +49%
Lower Limit (0%=OFF) -1 to -49%
Squeeze Period (SQ) 0 to 99 cycles
First Upslope Period (UP1) (included as part of the Weld 1 period) 0 to 9 cycles
First Weld Period (W1) 0 to 99 cycles
Cool Period 0 to 99 cycles
Second Upslope Period (UP2) (included as part of the Weld 2 period) 0 to 9 cyclesAPPENDIX A: TECHNICAL SPECIFICATIONS
Second Weld Period (W2) 0 to 99 cycles
Hold Period (HO) 0 to 99 cycles
Pulsation 1 to 9 complete Weld 2 periods
Voltage Compensation Mode:
Feedback Control Rate (maximum) 1 cycle
Current Accuracy (minimum) over a ±10% variation in input power
line voltage when welding at a 34% power factor ±3%
Currents 1 and 2 operating range (1% resolution) 0 to 99%
Current Monitor Operating Range:
Upper Limit (0 KA=OFF) 0.2 to 8.0 kA
Lower Limit (0 KA=OFF) 0.2 to 8.0 kA
Squeeze Period (SQ) 0 to 99 cycles
First Upslope Period (UP1) (included as part of the Weld 1 period) 0 to 9 cycles
First Weld Period (W1) 0 to 99 cycles
Cool Period 0 to 99 cycles
Second Upslope Period (UP2) (included as part of the Weld 2 period) 0 to 9 cycles
Second Weld Period (W2) 0 to 99 cycles
Hold Period (HO) 0 to 99 cycles
Pulsation 1 to 9 complete Weld 2 periods
Single Cycle Mode:
Feedback Control Rate None
Current Operating Range 0 to 99%
Current Monitor Operating Range, Upper/Lower Limit (0 KA=OFF) 0.2 to 8.0 kA
Squeeze Period (SQ) 0 to 99 cycles
Positive Half (+HALF)\ Negative Half (-HALF) Cycle Weld Period 0.5 cycle
Hold Period (HO) 0 to 99 cyclesAPPENDIX A: TECHNICAL SPECIFICATIONS
Welding Transformer Secondary to Primary Turns Ratio, Valves 1 and 2 1.0 to 199.9
External Power Requirement for Valve Drivers 1 and 2 24-115 Vac
Current Step-Up, Steps 1 to 5:
Step-up rate based on value of step 1, in increments of 1% 0 to 99%
Number of welds per step 0 to 9999
Welcard (Optional) Functions:
Welcard Schedule Card Capacity 91 weld schedules (7 schedules, 13 files/schedule)
Welcard Monitor 1 Card:
Parameters Stored Start No., Step No., Current 1 and Current 2 values, Time
Number of Parameters Stored (max) 3,584
Welcard Monitor 2 Card:
Parameters Stored Start No., Monitored Current ±%, Time
Number of Parameters Stored 7,168