QUINT POWER is the powerful 60 - 960 W DC power supply unit for universal use. With its wide-range input, single and three-phase versions, and international approval package, this solution is unrivalled. QUINT POWER provides reliable power supply: generously dimensioned capacitors ensure mains buffering of over 20 ms at full load. Full output power is provided by all three-phase devices, even in the event of a permanent phase failure. The Power Boost power reserve easily starts loads with high inrush currents and ensures that fuses are reliably tripped. Preventive function monitoring diagnoses impermissible operating states and minimizes downtimes in your system. Remote monitoring is provided by an active transistor switching output and a floating relay contact. All devices are idling-proof and short-circuit-proof, and are available with a regulated and adjustable output voltage of 12, 24, and 48 V DC with output currents of 2.5, 5, 10, 20, 30, and 40 A. Power supply units for use in Ex zone 2, uninterruptible solutions, AS-i power supply units, and a QUINT diode complete this comprehensive product range.
Specs from the Manufacturer:
Dimensions
Width
240 mm
Height
130 mm
Depth
125 mm
Width with alternative assembly
122 mm
Height with alternative assembly
130 mm
Depth with alternative assembly
243 mm
Back to top
Ambient conditions
Degree of protection
IP20
Ambient temperature (operation)
-25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
Ambient temperature (storage/transport)
-40 °C ... 85 °C
Max. permissible relative humidity (operation)
95 % (at 25 °C, non-condensing)
Climatic class
3K3 (in acc. with EN 60721)
Degree of pollution
2
Back to top
Input data
Nominal input voltage range
3x 400 V AC ... 500 V AC
Input voltage range
3x 320 V AC ... 575 V AC (for all three phases)
450 V DC ... 800 V DC
AC frequency range
45 Hz ... 65 Hz
Frequency range DC
0 Hz
Discharge current to PE
< 3.5 mA
Current consumption
approx. 3x 2.8 A (400 V AC)
approx. 3x 2.2 A (480 V AC)
Nominal power consumption
1048 W
Inrush current
< 15 A (typical)
Mains buffering time
> 20 ms (400 V AC)
> 20 ms (480 V AC)
Recommended breaker for input protection
3x 6 A ... 16 A (Characteristics B, C, D, K)
Type of protection
Transient surge protection
Protective circuit/component
Varistor
Back to top
Output data
Nominal output voltage
24 V DC ±1 %
Setting range of the output voltage (USet)
22.5 V ... 28.5 V (> 24 V DC, constant capacity restricted)
Nominal output current (IN)
40 A (-25 °C ... 70 °C)
POWER BOOST (IBoost)
45 A (-25°C ... 40°C permanent )
Derating
60 °C (2.5%/K)
Connection in parallel
yes, for redundancy and increased capacity
Connection in series
yes
Feedback voltage resistance
35 V DC
Protection against overvoltage at the output (OVP)
≤ 35 V DC
Max. capacitive load
unlimited
Active current limitation
Approx. IBOOST = 45 A (for short-circuit)
Control deviation
< 1 % (change in load, static 10 % ... 90 %)
< 2 % (change in load, dynamic 10 % ... 90 %)
< 0.1 % (change in input voltage ±10 %)
Residual ripple
< 10 mVPP (with nominal values)
Output power
960 W
Typical response time
< 1 s
Peak switching voltages nominal load
< 60 mVPP (20 MHz)
Maximum power dissipation in no-load condition
< 14 W
Power loss nominal load max.
< 80 W
Back to top
General
Net weight
3.5 kg
Operating voltage display
Green LED
Efficiency
> 91 % (for 230 V AC and nominal values)
MTBF (IEC 61709, SN 29500)
> 500000 h
Insulation voltage input/output
4 kV AC (type test)
2 kV AC (routine test)
Insulation voltage input / PE
3.5 kV AC (type test)
2 kV AC (routine test)
Insulation voltage output / PE
500 V DC (routine test)
Degree of protection
IP20
Protection class
I (with PE connection)
Mounting position
horizontal DIN rail NS 35, EN 60715
Assembly instructions
alignable: horizontally 0 mm, vertically 50 mm
Back to top
Connection data, input
Connection method
Screw connection
Conductor cross section solid min.
0.2 mm²
Conductor cross section solid max.
6 mm²
Conductor cross section flexible min.
0.2 mm²
Conductor cross section flexible max.
4 mm²
Conductor cross section AWG min.
24
Conductor cross section AWG max.
10
Stripping length
8 mm
Screw thread
M3
Back to top
Connection data, output
Connection method
Screw connection
Conductor cross section solid min.
0.5 mm²
Conductor cross section solid max.
16 mm²
Conductor cross section flexible min.
0.5 mm²
Conductor cross section flexible max.
10 mm²
Conductor cross section AWG min.
20
Conductor cross section AWG max.
6
Stripping length
10 mm
Screw thread
M4
Back to top
Signaling
Output name
DC OK active
Output description
UOUT > 0.9 x UN: High signal
Maximum switching voltage
≤ 24 V
Output voltage
+ 24 V DC (Signal)
Maximum inrush current
≤ 40 mA
Continuous load current
≤ 40 mA
Status display
"DC OK" LED green
Note on status display
UOUT < 0.9 x UN: LED flashing
Conductor cross section solid min.
0.5 mm²
Conductor cross section solid max.
16 mm²
Conductor cross section flexible min.
0.5 mm²
Conductor cross section flexible max.
10 mm²
Conductor cross section AWG min.
20
Conductor cross section AWG max.
6
Tightening torque, min
1.2 Nm
Tightening torque max
1.5 Nm
Screw thread
M4
Output name
DC OK floating
Output description
Relay contact, UOUT > 0.9 x UN: Contact closed
Maximum switching voltage
≤ 30 V AC/DC
Maximum inrush current
≤ 1 A
Continuous load current
≤ 1 A
Status display
"DC OK" LED green
Back to top
Standards and Regulations
Electromagnetic compatibility
Conformance with EMC Directive 2014/30/EU
Noise emission
EN 55011 (EN 55022)
Noise immunity
EN 61000-6-2
Connection in acc. with standard
CUL
Standards/regulations
EN 61000-4-2
Contact discharge
8 kV
Standards/regulations
EN 61000-4-3
Frequency range
80 MHz ... 2 GHz
Test field strength
10 V/m
Standards/regulations
EN 61000-4-4
Comments
Criterion B
Standards/regulations
EN 61000-6-3
EN 61000-4-6
Frequency range
0.15 MHz ... 80 MHz
Voltage
10 V
Standards/regulations
EN 61000-4-11
Low Voltage Directive
Conformance with Low Voltage Directive 2014/35/EC
Standard - Electrical safety
EN 62368-1
Standard – Safety extra-low voltage
EN 62368-1 (SELV)
EN 60204 (PELV)
Standard - Safe isolation
DIN VDE 0100-410
Standard – Protection against shock currents, basic requirements for protective separation in electrical equipment
EN 62368-1
Standard – Limitation of mains harmonic currents
EN 61000-3-2
Standard - Equipment safety
GS (tested safety)
Shipbuilding approval
DNV GL (EMC A)
UL approvals
UL/C-UL listed UL 508
UL/C-UL Recognized UL 60950-1
UL/C-UL Listed UL 1604 Class I, Division 2, Groups A, B, C, D
Shock
18 ms, 30g, in each space direction (according to IEC 60068-2-27)
Vibration (operation)
< 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6)
15 Hz ... 150 Hz, 2.3g, 90 min.
Certificate
CB Scheme
Overvoltage category (EN 62477-1)
III