-40%

Phoenix Contact QUINT-PS-3X400-500AC/24DC/40 Power Supply 24VDC 40A 3Ph 2938646

$ 158.39

Availability: 100 in stock
  • All returns accepted: Returns Accepted
  • Brand: PHOENIX CONTACT
  • Return shipping will be paid by: Buyer
  • Model: 2938646 QUINT-PS-3X400-500AC/24DC/40
  • Product Brand: PHOENIX CONTACT
  • Output Voltage: 24 V-DC
  • Product Condition: Used
  • Output Current: 40 A AMP
  • Model Number: 2938646 QUINT-PS-3X400-500AC/24DC/40
  • Adjustable Power Supply Type: Switch-Mode Power Supply (SMPS)
  • MPN: 2938646 QUINT-PS-3X400-500AC/24DC/40
  • Refund will be given as: Money Back
  • Input Voltage: 400 - 500 V-AC
  • Item must be returned within: 30 Days
  • Condition: In excellent used condition, pulled from working equipment that was only in service for less than 1 year.

    Description

    Phoenix Contact QUINT-PS-3X400-500AC/24DC/40 Din Rail Power Supply 24VDC 40A 3-Phase 2938646
    In excellent used condition, pulled from working equipment that was only in service for less than 1 year.
    Product Description from the Manufacturer:
    QUINT POWER is the powerful 60 - 960 W DC power supply unit for universal use. With its wide-range input, single and three-phase versions, and international approval package, this solution is unrivalled. QUINT POWER provides reliable power supply: generously dimensioned capacitors ensure mains buffering of over 20 ms at full load. Full output power is provided by all three-phase devices, even in the event of a permanent phase failure. The Power Boost power reserve easily starts loads with high inrush currents and ensures that fuses are reliably tripped. Preventive function monitoring diagnoses impermissible operating states and minimizes downtimes in your system. Remote monitoring is provided by an active transistor switching output and a floating relay contact. All devices are idling-proof and short-circuit-proof, and are available with a regulated and adjustable output voltage of 12, 24, and 48 V DC with output currents of 2.5, 5, 10, 20, 30, and 40 A. Power supply units for use in Ex zone 2, uninterruptible solutions, AS-i power supply units, and a QUINT diode complete this comprehensive product range.
    Specs from the Manufacturer:
    Dimensions
    Width
    240 mm
    Height
    130 mm
    Depth
    125 mm
    Width with alternative assembly
    122 mm
    Height with alternative assembly
    130 mm
    Depth with alternative assembly
    243 mm
    Back to top
    Ambient conditions
    Degree of protection
    IP20
    Ambient temperature (operation)
    -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
    Ambient temperature (storage/transport)
    -40 °C ... 85 °C
    Max. permissible relative humidity (operation)
    95 % (at 25 °C, non-condensing)
    Climatic class
    3K3 (in acc. with EN 60721)
    Degree of pollution
    2
    Back to top
    Input data
    Nominal input voltage range
    3x 400 V AC ... 500 V AC
    Input voltage range
    3x 320 V AC ... 575 V AC (for all three phases)
    450 V DC ... 800 V DC
    AC frequency range
    45 Hz ... 65 Hz
    Frequency range DC
    0 Hz
    Discharge current to PE
    < 3.5 mA
    Current consumption
    approx. 3x 2.8 A (400 V AC)
    approx. 3x 2.2 A (480 V AC)
    Nominal power consumption
    1048 W
    Inrush current
    < 15 A (typical)
    Mains buffering time
    > 20 ms (400 V AC)
    > 20 ms (480 V AC)
    Recommended breaker for input protection
    3x 6 A ... 16 A (Characteristics B, C, D, K)
    Type of protection
    Transient surge protection
    Protective circuit/component
    Varistor
    Back to top
    Output data
    Nominal output voltage
    24 V DC ±1 %
    Setting range of the output voltage (USet)
    22.5 V ... 28.5 V (> 24 V DC, constant capacity restricted)
    Nominal output current (IN)
    40 A (-25 °C ... 70 °C)
    POWER BOOST (IBoost)
    45 A (-25°C ... 40°C permanent )
    Derating
    60 °C (2.5%/K)
    Connection in parallel
    yes, for redundancy and increased capacity
    Connection in series
    yes
    Feedback voltage resistance
    35 V DC
    Protection against overvoltage at the output (OVP)
    ≤ 35 V DC
    Max. capacitive load
    unlimited
    Active current limitation
    Approx. IBOOST = 45 A (for short-circuit)
    Control deviation
    < 1 % (change in load, static 10 % ... 90 %)
    < 2 % (change in load, dynamic 10 % ... 90 %)
    < 0.1 % (change in input voltage ±10 %)
    Residual ripple
    < 10 mVPP (with nominal values)
    Output power
    960 W
    Typical response time
    < 1 s
    Peak switching voltages nominal load
    < 60 mVPP (20 MHz)
    Maximum power dissipation in no-load condition
    < 14 W
    Power loss nominal load max.
    < 80 W
    Back to top
    General
    Net weight
    3.5 kg
    Operating voltage display
    Green LED
    Efficiency
    > 91 % (for 230 V AC and nominal values)
    MTBF (IEC 61709, SN 29500)
    > 500000 h
    Insulation voltage input/output
    4 kV AC (type test)
    2 kV AC (routine test)
    Insulation voltage input / PE
    3.5 kV AC (type test)
    2 kV AC (routine test)
    Insulation voltage output / PE
    500 V DC (routine test)
    Degree of protection
    IP20
    Protection class
    I (with PE connection)
    Mounting position
    horizontal DIN rail NS 35, EN 60715
    Assembly instructions
    alignable: horizontally 0 mm, vertically 50 mm
    Back to top
    Connection data, input
    Connection method
    Screw connection
    Conductor cross section solid min.
    0.2 mm²
    Conductor cross section solid max.
    6 mm²
    Conductor cross section flexible min.
    0.2 mm²
    Conductor cross section flexible max.
    4 mm²
    Conductor cross section AWG min.
    24
    Conductor cross section AWG max.
    10
    Stripping length
    8 mm
    Screw thread
    M3
    Back to top
    Connection data, output
    Connection method
    Screw connection
    Conductor cross section solid min.
    0.5 mm²
    Conductor cross section solid max.
    16 mm²
    Conductor cross section flexible min.
    0.5 mm²
    Conductor cross section flexible max.
    10 mm²
    Conductor cross section AWG min.
    20
    Conductor cross section AWG max.
    6
    Stripping length
    10 mm
    Screw thread
    M4
    Back to top
    Signaling
    Output name
    DC OK active
    Output description
    UOUT > 0.9 x UN: High signal
    Maximum switching voltage
    ≤ 24 V
    Output voltage
    + 24 V DC (Signal)
    Maximum inrush current
    ≤ 40 mA
    Continuous load current
    ≤ 40 mA
    Status display
    "DC OK" LED green
    Note on status display
    UOUT < 0.9 x UN: LED flashing
    Conductor cross section solid min.
    0.5 mm²
    Conductor cross section solid max.
    16 mm²
    Conductor cross section flexible min.
    0.5 mm²
    Conductor cross section flexible max.
    10 mm²
    Conductor cross section AWG min.
    20
    Conductor cross section AWG max.
    6
    Tightening torque, min
    1.2 Nm
    Tightening torque max
    1.5 Nm
    Screw thread
    M4
    Output name
    DC OK floating
    Output description
    Relay contact, UOUT > 0.9 x UN: Contact closed
    Maximum switching voltage
    ≤ 30 V AC/DC
    Maximum inrush current
    ≤ 1 A
    Continuous load current
    ≤ 1 A
    Status display
    "DC OK" LED green
    Back to top
    Standards and Regulations
    Electromagnetic compatibility
    Conformance with EMC Directive 2014/30/EU
    Noise emission
    EN 55011 (EN 55022)
    Noise immunity
    EN 61000-6-2
    Connection in acc. with standard
    CUL
    Standards/regulations
    EN 61000-4-2
    Contact discharge
    8 kV
    Standards/regulations
    EN 61000-4-3
    Frequency range
    80 MHz ... 2 GHz
    Test field strength
    10 V/m
    Standards/regulations
    EN 61000-4-4
    Comments
    Criterion B
    Standards/regulations
    EN 61000-6-3
    EN 61000-4-6
    Frequency range
    0.15 MHz ... 80 MHz
    Voltage
    10 V
    Standards/regulations
    EN 61000-4-11
    Low Voltage Directive
    Conformance with Low Voltage Directive 2014/35/EC
    Standard - Electrical safety
    EN 62368-1
    Standard – Safety extra-low voltage
    EN 62368-1 (SELV)
    EN 60204 (PELV)
    Standard - Safe isolation
    DIN VDE 0100-410
    Standard – Protection against shock currents, basic requirements for protective separation in electrical equipment
    EN 62368-1
    Standard – Limitation of mains harmonic currents
    EN 61000-3-2
    Standard - Equipment safety
    GS (tested safety)
    Shipbuilding approval
    DNV GL (EMC A)
    UL approvals
    UL/C-UL listed UL 508
    UL/C-UL Recognized UL 60950-1
    UL/C-UL Listed UL 1604 Class I, Division 2, Groups A, B, C, D
    Shock
    18 ms, 30g, in each space direction (according to IEC 60068-2-27)
    Vibration (operation)
    < 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6)
    15 Hz ... 150 Hz, 2.3g, 90 min.
    Certificate
    CB Scheme
    Overvoltage category (EN 62477-1)
    III
    FREE SHIPPING TO THE LOWER 48 UNITED STATES, CAN SHIP WORLDWIDE IMMEDIATELY. MESSAGE US FOR AN INTERNATIONAL SHIPPING QUOTE TODAY!